www.hezhongindotama.com
Home | About Us | About Hezhong | Product Catalog | Certificate | F.A.Q | Support | Career

Coming Soon...!!!


 HI12 Inverter
 
Features
 
•  Patent technologies including tree-type radiator, pulse transformer etc.
•  Multiple protections and latest components
•  Surface-mounting technology
•  Programmable output terminals and relay output terminals
•  Panel potentiometer for fine tuning of output frequency
•  Unique heat dissipation design
 
Application
Applicable to fans and pumps in various sectors.
 
Type Description
Series code Phase Capacity
HI12 S £º 3-phase 0.75 ¡« 280kW
 
Standard Specifications
400V Series
Type 0.75 1.5 2.2 3.7 5.5 7.5 11 15
18.5 22 30 37 45 55 75 90
110 132 160 200 220 280    
Applicable
motor capacity
(kW)
0.75 1.5 2.2 3.7 5.5 7.5 11 15
18.5 22 30 37 45 55 75 90
110 132 160 200 220 280    
Rated output Rated capacity
(kVA)
1.6 2.4 3.6 5.9 8.5 12 16 20
25 30 40 49 60 74 99 116
138 167 200 248 273 342    
Rated current (A) 2.5 3.7 5.5 9.0 13 18 24 30
38 45 60 75 91 112 150 176
210 253 304 377 415 520    
Overload capability 120% of rated current for 1 minute
Voltage(V) 3-phase 0~380V
Input Power 3-phase 380V 50/60Hz
Fluctuation Voltage £º +10~-15%(temporary fluctuation ¡À15%) Frequency £º ¡À2%
Braking Braking selection 0.75~15KW £º external braking resistor
18.5~280KW £º external braking unit
 
Common Specifications
Item Description
Control V/F characteristics V/F-curve control
Torque boost 0: Automatically adjusts the torque to the optimum value according to the load condition
1 ¡« 50: Manual setting
Accel/Decel time 0.1 ¡« 3600S. Acceleration and deceleration time can be set separately.
Additional functions Upper-/lower-limit frequency, jump frequency, current limiting, bias frequency, frequency gain, auto-reset, AVR
PID Manually setting the PI parameter
P £º 1 ¡« 8000 I £º 1.0 ¡« 500.0S
Multi-motor mode The inverter can control up to 4 motors simultaneously. 3 main motors can be set as inverter operation or commercial power operation, thus simplifying the constant-pressure water supply system.
Timing motor-
alternation
In a multi-motor system, the function of timing motor-alternation should be set in order that individual motors have the same operating time. When the continuous operating time of a motor reaches the set value and there is another motor in stop state, the inverter will automatically switch the operation between thees two motors(that is, the running motor stops, the other one starts) .
Motor-alternation time: 0 ¡« 1000 hours.
Sleep When feedback value>sleep level and the operation frequency is less than the sleep frequency £¬ the main motor stops £» When sleep level ¡Ý feedback value ¡Ý wake level £¬ the donkey motor starts.
Wake When feedback value< motor donkey the and starts main £¬ level>
Fire-fighting control When a certain pressure of water supply is required, short terminals FA and CM.
Water level control Automatically detects the water level to control the start and stop of the inverter.
Timing on/off Selects the length of time before the inverter is automatically started and stopped £¬ 0 ¡« 24.0h
Max. voltage frequency 10 ¡« 120Hz
Frequency setting Keypad panel £º¡Ä / ¡Å keys and potentiometer(option)
External terminals: X4, X5
Analog signals: VRF, VPF, IRF, IPF
Command source Keypad panel: RUN & STOP keys External terminals: FWD, REV
Output signal Relay output: A1, B1, C1, A2, B2, C2
Control output: Y1, Y2
Analog output: FMA
Environment Service site Indoor and below 1000m
Temperature/
humidity
-10 ¡« 40 ¡æ /20 ¡« 90% RH, non-condensation
Vibration Below 5.9m /s 2 £¨ 0.6G £©
Storage temperature -20 ¡« 65 ¡æ
Protection function Overcurrent, short circuit, overvoltage, under voltage, overload, overheating, motor overload, external alarm
Protection degree IP10
Cooling method Forced air cooling
 
Outline Drawing
 

 

 

 
Copyright @www.Hezhongindotama.com All Right reserved