| Item |
Description |
| Control |
V/F characteristics |
V/F-curve control |
| Torque boost |
0: Automatically adjusts the torque to the optimum value according to the load condition
1 ¡« 50: Manual setting |
| Accel/Decel time |
0.1 ¡« 3600S. Acceleration and deceleration time can be set separately. |
| Additional functions |
Upper-/lower-limit frequency, jump frequency, current limiting, bias frequency, frequency gain, auto-reset, AVR |
| PID |
Manually setting the PI parameter
P £º 1 ¡« 8000 I £º 1.0 ¡« 500.0S |
| Multi-motor mode |
The inverter can control up to 4 motors simultaneously. 3 main motors can be set as inverter operation or commercial power operation, thus simplifying the constant-pressure water supply system. |
Timing motor-
alternation |
In a multi-motor system, the function of timing motor-alternation should be set in order that individual motors have the same operating time. When the continuous operating time of a motor reaches the set value and there is another motor in stop state, the inverter will automatically switch the operation between thees two motors(that is, the running motor stops, the other one starts) .
Motor-alternation time: 0 ¡« 1000 hours. |
| Sleep |
When feedback value>sleep level and the operation frequency is less than the sleep frequency £¬ the main motor stops £» When sleep level ¡Ý feedback value ¡Ý wake level £¬ the donkey motor starts. |
| Wake |
When feedback value< motor donkey the and starts main £¬ level> |
| Fire-fighting control |
When a certain pressure of water supply is required, short terminals FA and CM. |
| Water level control |
Automatically detects the water level to control the start and stop of the inverter. |
| Timing on/off |
Selects the length of time before the inverter is automatically started and stopped £¬ 0 ¡« 24.0h |
| Max. voltage frequency |
10 ¡« 120Hz |
| Frequency setting |
Keypad panel £º¡Ä / ¡Å keys and potentiometer(option)
External terminals: X4, X5
Analog signals: VRF, VPF, IRF, IPF |
| Command source |
Keypad panel: RUN & STOP keys External terminals: FWD, REV |
| Output signal |
Relay output: A1, B1, C1, A2, B2, C2
Control output: Y1, Y2
Analog output: FMA |
| Environment |
Service site |
Indoor and below 1000m |
Temperature/
humidity |
-10 ¡« 40 ¡æ /20 ¡« 90% RH, non-condensation |
| Vibration |
Below 5.9m /s 2 £¨ 0.6G £© |
| Storage temperature |
-20 ¡« 65 ¡æ |
| Protection function |
Overcurrent, short circuit, overvoltage, under voltage, overload, overheating, motor overload, external alarm |
| Protection degree |
IP10 |
| Cooling method |
Forced air cooling |