www.hezhongindotama.com
Home | About Us | About Hezhong | Product Catalog | Certificate | F.A.Q | Support | Career

Coming Soon...!!!


 HI40 Inverter
 
Features
 
•  Patent technologies including tree-type radiator, pulse transformer etc.
•  Multiple protections and latest components
•  Surface-mounting technology
•  Programmable output terminals and relay output terminals
•  Panel potentiometer for fine tuning of output frequency
•  Unique heat dissipation design
 
Application
Widely used in petroleum, petrochemical, machinery, textile, printing, packaging, ceramics, and pharmacy industry etc.
 
Type Description
Series code Phase Capacity
HI40 S £º 3-phase
D: single phase
0.75 ¡« 280kW
 
Standard Specifications
400V Series
Type 0.75 1.5 2.2 3.7 5.5 7.5 11 15
18.5 22 30 37 45 55 75 90
110 132 160 200 220 280    
Applicable
motor capacity
(kW)
0.75 1.5 2.2 3.7 5.5 7.5 11 15
18.5 22 30 37 45 55 75 90
110 132 160 200 220 280    
Rated output Rated capacity
(kVA)
1.6 2.4 3.6 5.9 8.5 12 16 20
25 30 40 49 60 74 99 116
138 167 200 248 273 342    
Rated current (A) 2.5 3.7 5.5 9.0 13 18 24 30
38 45 60 75 91 112 150 176
210 253 304 377 415 520    
Overload capability 150% 1 minute
Voltage(V) 3-phase 0~380V
Input Power 3-phase 380V 50/60Hz
Fluctuation Voltage £º +10~-15%(temporary ¡À15%) Frequency £º ¡À2%
Braking Braking selection 0.75~15KW £º external braking resistor
18.5~280KW £º external braking unit
DC braking DC braking starting frequency, DC braking amount, DC braking time
 
Common Specifications
Item Specification
Control V/F characteristics V/F curve control
Torque boost 0 ¡« 50
Accel/decel time 0.1 ¡« 3600S £¬ 4 accel/decel time
Pattern operation 7 multistep frequencies £¬ 4 pattern operation modes
Auxiliary function Upper-limit frequency, lower-limit frequency, jump frequency, current limiting, bias frequency, frequency gain, stall control, auto-reset, S-curve accel/decel, jog run, AVR, auto energy-saving
Output Max. frequency 50 ¡« 400Hz
Base frequency 10 ¡« 400Hz
Frequency setting Keypad panel £º¡Ä / ¡Å keys and potentiometer
External terminal £º X4, X5
Analog signal £º VRF, IRF
Command source Keypad panel £º RUN or STOP key
External terminal £º FWD, REV
Output signal Relay output £º 30A , 30B, 30C
Multi-function output: Y1 ¡¢ Y2 ¡¢ Y3
Analog output: FMA
Display LED monitor Frequency, current, voltage, speed, line speed, load rate
Indicator Charging, unit, keypad panel operation, running
Environment Service site Indoor, below 1000m altitude
Temperature/humidity £­ 10 ¡« 40 ¡æ /20 ¡« 90% RH, non-condensation
Vibration Less than 5.9m /s 2 £¨ 0.6G £©
Storage temperature £­ 20 ¡« 65 ¡æ
Protection function Module fault(FL), overvoltage(ouu), undervoltage(Lou), overload(oL), overheating(oH), external alarm(oLE), braking resistor overheating(dbr), motor overload
Protection degree IP10
Cooling method Forced air cooling
 
Outline Drawing

 

 

 
Copyright @www.Hezhongindotama.com All Right reserved