 HI60/61 Inverter
 
HI60 HI61
 
Features
 
•  Advanced sensorless vector control and quasi-superconduction technologies
•  High speed DSP chip and high performance IGBT module
•  Motor auto-tuning
•  Standard RS485 interface
•  Easy PLC control and built-in PID
•  Excellent EMC
•  Elegant and modern appearance
•  IP 20 protection degree
•  Multiple frequency setting modes
 
Application
Widely used in petroleum, petrochemical, machinery, textile, printing, packaging, ceramics, and pharmacy industry etc.
 
Type Description
Series code Phase Capacity
HI60(HI61) G : General-purpose
P : Pumps & Fans
HI60: 0.75 ¡« 15KW
HI61: 15 ¡« 315KW
 
Standard Specifications
HI 60G Series
HI 60G 0.75 1.5 2.2 4 5.5 7.5 11
Motor capacity (KW) 0.75 1.5 2.2 4 5.5 7.5 11
Output Rated capacity (KVA) 1.6 2.4 3.6 6.4 8.5 12 16
Rated current (A) 2.5 3.7 5.5 9.7 13 18 24
Voltage (V) 0 ¡« 380V 0 ¡« 400 Hz
Overload capacity 150% 1 minute
Power supply 3-phase 380V 50/60Hz

HI60P Series
HI60P 1.5 2.2 4 5.5 7.5 11 15
Motor capacity (KW) 1.5 2.2 4 5.5 7.5 11 15
Output 2.4 3.6 6.4 8.5 12 16 20  
3.7 5.5 9.7 13 18 24 30  
Voltage (V) 0 ¡« 380V 0 ¡« 400 Hz
Overload capacity 120% 1 minute
Power supply 3-phase 380V 50/60Hz

HI 61G Series
HI 61G 15 18.5 22 30 37 45 55 75
90 110 132 160 200 250 315  
Motor capacity (KW) 15 18.5 22 30 37 45 55 75
90 110 132 160 200 250 315  
Output Rated capacity (KVA) 20 25 30 40 49 60 74 99
116 138 167 200 248 310 389  
Rated current (A) 30 38 45 60 75 91 112 150
176 210 253 304 377 475 590  
Voltage (V) 0 ~ 380V 0 ~ 400 Hz
Overload capacity 150% 1 minute

Power supply

3-phase 380V 50/60Hz


HI61P Series
HI61P 18.5 22 30 37 45 55 75 90
110 132 160 200 250 315    
Motor capacity (KW) 18.5 22 30 37 45 55 75 90
110 132 160 200 250 315    
Output Rated capacity (KVA) 25 30 40 49 60 74 99 116
138 167 200 248 310 389    
Rated current (A) 38 45 60 75 91 112 150 176
210 253 304 377 475 590    
Voltage (V) 0 ~ 380V 0 ~ 400 Hz
Overload capacity 120% 1 minute
Power supply 3-phase 380V 50/60Hz
 
Common Specifications
Control Modulation mode Field-oriented vector control PWM
Control mode V/F control mode: open-loop and closed-loop Vector control mode: speed sensor-less and PG speed sensor
V/F curve Linear or random V/F curve, up to six step V/F curves can be set by users
Frequency setting mode Four main and four auxiliary setting modes. Auxiliary settings are superimposed on the main ones;
Analog input (VR1, VR2, IR1 & IR2);
Computer setting(via RS485).
Acceleration/ deceleration control Eight acceleration/deceleration times £¬ 0 ¡« 3600S £¬ linear or S-curve mode
Pattern operation mode Five modes, fifteen step frequencies
Additional functions Upper-limit frequency, lower-limit frequency, jump frequency, current limit, stall control, auto reset, auto energy-saving operation, auto voltage regulation, auto-restart after momentary power failure
Run Command setting Panel setting;
External terminal setting(X1~X7);
Computer setting(via RS485)
Input signal Multi-function external terminal inputs X1 ¡« X7
Output signal Multi-function output (Y1 ¡« Y3 £¬ DC 24V/50mA) £»
Relay output( 30A , 30B & 30C , AC 240V/ 1A )
Braking function HI60: External braking resistor
HI61: External braking unit and braking resistor
Protection function Overcurrent, short circuit, grounding fault, overvoltage, undervoltage, overload, overheating, phase failure, external alarm
Ambient Service site Indoor and below 1000m altitude
Temperature/ humidity -10 ¡« + 40 ¡æ /20 ¡« 90% RH, no condensation
Vibration Less than 5.9m /s2 ( 0.6G )
Storage temperature -20 ¡« + 60 ¡æ
Cooling method Forced air cooling
Protection degree IP20
 
Outline Drawing
HI60 series

HI61 series

 

 

 